- Imaging of endocrinal systemد.أحمد بدير25-26
- Pitutary gland⬅️ Dynamic MRI.
- Thyroid gland⬅️ Ultrasound.
- parathyroid ⬅️ Isotope scan.
- suprarenal ⬅️ Dynamic CT
- Specify the TIRADS classification criteria for performing Fine Needle Aspiration (FNA) in thyroid nodules.
- The most accurate imaging modality for localizing a parathyroid adenoma is an Isotope scan (Technetium Sestamibi).
- The most accurate imaging modality for detecting small pancreatic endocrine tumors like insulinomas is Transesophageal (Endoscopic) Ultrasound.
- The preferred imaging protocol for differentiating between benign and malignant adrenal masses is the Dynamic CT Adrenal (Wash-out) Protocol
- Ultrasound is the primary method for imaging testes and ovaries, the most accurate modality for definitive diagnosis is MRI.